Instructions for the Installer
10. ADAPTING TO DIFFERENT TYPES OF GAS
Before carrying out the operations described below, disconnect the
appliance from the electricity supply.
The appliance is tested with natural gas NG (2H) at the pressure of 1.0
kPa. If it is to be used with other types of gas, the burner nozzles have to
be changed and the gas taps adjusted to set the minimum flame. To
replace the nozzles, proceed as described below.
10.1 Changing the hob nozzles
1 Remove the pan stands, all the burner caps and the flame diffuser
rings
2 Use a 7 mm socket wrench to unscrew the burner nozzles;
3 Replace the burner nozzles depending on the type of gas to be used
(see point "10.2 Burner and nozzle characteristics table").
4 Put the burners back into place correctly.