TRANSFORMATIONS
Before any kind of transformation is necessary
to cut off the electricity.
6) TRANSFORMATION OF THE INPUT
TYPE
The standard equipment of the appliances is for
single phase connection. In any case, under proper
changes, they can be fed with a three phase
system.
To obtain these changes, please, follow the
instructions:
a) Take off the panel stuck by screws "V" (see
fig. 14).
b) Remove the connection jumpers on the clamp
following the scheme of fig.15 of page (attached on
the body).
c) Insert the input cable with adequate section (see
scheme paragraph 5) into the chock.
d) Connect the phase cable into the clamp and the
"earth" cable in the relative clamp.
e) Hold up the input cable with the pertinent
stopcable.
f) Replace the panel in its seat and hold up with the
pertinent screws "V" (see fig. 14).
FIG. 14