Instructions for the installer
35
6.6 Gas connection
Connection to the gas supply network can be made using a rigid copper hose or
a flexible steel hose with a continuous wall and in compliance with the guidelines
established by the applicable standard.
Once the operation is complete, check the hose fittings for leaks using a soapy
solution; never use a flame.
The hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. To set it up
for supply using other types of gas, see “3. ADAPTATION TO DIFFERENT
TYPES OF GAS”. The gas inlet connection is threaded ½” external gas (ISO
228-1).
Connection with a rigid copper
hose:The connection to the gas supply
network must be made in such a way that it
does not cause stresses of any type on the
appliance.
The connection can be made using the
adapter unit D with double cone, always
inserting gasket C (provided) in between.
Connection with a flexible steel
hose:Use only continuous wall stainless
steel hoses that comply with current
legislation, making sure to always insert
the supplied gasket C between the
connection A and the flexible hose B.
Installation with the flexible hose must be carried out so that the length of the
piping does not exceed 2 metres when fully extended; make sure that the hoses
do not come into contact with moving parts and that they are not crushed in any
way.
6.7 Connection to liquid gas
Use a pressure regulator and make the connection on the gas cylinder following
the guidelines set out in the regulations in force.
Make sure that the supply pressure complies with the values indicated in the
table shown in the paragraph "7.2 Burner and nozzle characteristics table”.