Instructions for the Installer
8
Overall dimensions: location of gas and electrical connection points
(all measures in mm).
A 110
B 760
C 170
D 150
2.3 Gas connection
This appliance is suitable for installation with Natural
Gas or ULPG (propane). Refer to page 13 for the
relevant burner pressure and appropriate injector
sizes. When the appliance is to be connected to
Natural Gas then the pressure regulator supplied must
be fitted to the gas inlet. A test point (for checking the
gas pressure) is supplied either with the regulator or as
a separate fitting in the case of LPG (propane)
appliances.
Connection of the appliance to the gas supply must be
in accordance with the requirements of AS5601. A ½”
BSP connector at the inlet is recommended and the
gas supply line to the appliance must be of adequate
length to allow sufficient withdrawal of appliance for
service or disconnection and be:
1) annealed copper pipe or;
2) Flexible hose according to AS/NZ1869 & be at
least Class “B”, 10 mm diameter, max length 100
mm.
The cooker must be installed with provision to allow
the gas to be turned off and disconnected for servicing
and removal of the appliance as required from the gas
supply.