Instructions for the installer
9
3.3
Room ventilation
The appliance may only be installed in constantly ventilated rooms, in accordance with the
regulations in force. The room where the appliance is installed must provide sufficient air for frequent
gas combustion and the renewal of the air in the room. The air intakes, which are protected by grates,
must be of a suitable size (in accordance with the regulations in force) and be placed where they
cannot be obstructed either wholly or partially. The openings must enable 2 m
3
/h of air to enter per
kW of gas power of the appliance.
The kitchen must be suitably ventilated in order to eliminate the heat and humidity produced by
cooking. In particular, after extended use, you are advised to open a window or step up the speed of
any fans in use.
3.4 Discharge of combustion products
Combustion products must be discharged by means of a hood connected to a reliable naturally
drawing chimney or one using forced suction. An effective suction system must be carefully designed
by a specialist, respecting the positions and distances set out in the relevant regulation. When the
installation is complete, the installer must provide a certificate of conformity.